Power 220V laboratory Plaster Softening Point Tester automatic detection

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xTest Range | Room Temperature -100℃ | Temperature Rise | Automatic Detection |
---|---|---|---|
Ring | 2020 Chinese Pharmacopoeia 2102 Plaster Softening Point Determination Method | Timing Range | 0-99 Minutes And 99 Seconds |
Test Sample | Plaster | Test Item | Softening Point |
Heating Rate | 1-1.5℃/min As Stipulated In The Pharmacopoeia | Temperature Measurement Accuracy | 0.1℃ |
External Dimension | 340×230×340mm | Weight | 12KG |
Power Supply Voltage | 220V | ||
Highlight | 220V Plaster Softening Point Tester,Laboratory Plaster Softening Point Tester,automatic detection Plaster Softening Point Tester |
ST104 A Plaster softening point tester
ST104A Plaster softening point meter/tester is designed and manufactured strictly in accordance with the method for the determination of the softening point of ointments 2102 in 2020. This method is used for the determination of the temperature when the plaster is softened by heat under specified conditions, that is, the temperature when the plaster falls to 25mm due to heat according to the following method.
It can be used to detect the aging degree of the plaster and indirectly reflect the viscosity of the plaster.
Test range | room temperature -100℃ |
Temperature rise | automatic detection |
ring | 2020 Chinese Pharmacopoeia 2102 plaster softening point determination method |
Timing range | 0-99 minutes and 99 seconds |
Test sample | Plaster |
Test Item | softening point |
Heating rate | 1-1.5℃/min as stipulated in the pharmacopoeia |
Temperature measurement accuracy | 0.1℃ |
External dimension | 340×230×340mm |
Weight | 12KG |
Power supply voltage | 220V |
Main Technical indicators
1.Test range: room temperature -100℃
2.Temperature rise:automatic detection.
3.Ring:2020 Chinese Pharmacopoeia 2102 plaster softening point determination method
4.Timing range:0-99 minutes and 99 seconds
5.Temperature measurement accuracy:0.1℃
6.Heating rate:1-1.5℃/min as stipulated in the pharmacopoeia
7.External dimension:340×230×340mm
8.Weight:12KG
9.Power supply voltage:220V
Main Features:
1.The temperature is controlled by the instrument without human error.
2.High precision temperature probe, sensitive to temperature.
3.strong magnetic stirring device, the test temperature is more uniform
4.Liquid crystal display screen, can display the temperature in real time.
5.Can measure high temperature, medium is water or glycerine.
S/N | name | specifications | Quantity | Remarks |
1 | softening point meter | host | 1 | |
2 | Ball fixing ring | 2 | Conforming to pharmacopoeia | |
3 | The sample ring | 2 | ||
4 | Steel ball | 2 | ||
5 | T power cord | 1 | ||
6 | Printing paper | 2 | ||
7 | Certificate warranty card | 1 | ||
8 | instructions | 1 |
ST104A Plaster softening point meter/tester is designed and manufactured strictly in accordance with the method for the determination of the softening point of ointments 2102 in 2020. This method is used for the determination of the temperature when the plaster is softened by heat under specified conditions, that is, the temperature when the plaster falls to 25mm due to heat according to the following method.
It can be used to detect the aging degree of the plaster and indirectly reflect the viscosity of the plaster.
Test range | room temperature -100℃ |
Temperature rise | automatic detection |
ring | 2020 Chinese Pharmacopoeia 2102 plaster softening point determination method |
Timing range | 0-99 minutes and 99 seconds |
Test sample | Plaster |
Test Item | softening point |
Heating rate | 1-1.5℃/min as stipulated in the pharmacopoeia |
Temperature measurement accuracy | 0.1℃ |
External dimension | 340×230×340mm |
Weight | 12KG |
Power supply voltage | 220V |