All Products
-
Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Phone Number :
+8615665870097
WhatsApp :
+8613805402265
16G Storage Edible Oil Quality Analyzer GB/T5009.37 Acid Value Range 0-50.000
Acid Value Range: | 0-50.000 ( KOH )/( Mg/g ) |
---|---|
Range Of Peroxide Value: | 0-236000mmol/kg ( 0-0.600g/100g ) |
Detection Principle: | National Standard Titration Method |
GB/T 20795 Full-Automatic Oil Smoke Point Wavelength 380-780nm Range Rt To 400 ℃
Range: | Room Temperature To 400 ℃ |
---|---|
Repeatability: | ≤ 2℃ |
Reproducibility: | ≤ 4℃ |
Accuracy 0.0002 Abbe Refractometer Sugar Density M/S 0-95% M/S ND=1.3000-1.7000
Sugar Density M/S: | 0-95% |
---|---|
Measuring Range: | ND=1.3000-1.7000 |
ND Minimum Division Value: | 0.0005 |
ND=1.300-1.700 Abbe Refractometer For Edible Oil ST121A ND Division Value Min 0.0005
Measurement Range: | ND=1.300-1.700 |
---|---|
Measurement Accuracy: | 0.0002 |
Minimum Division Value Of Refractive Index (ND): | 0.0005 |
Test Stroke 200mm Particle Crushing Strength Tester Speed 0.5-500mm/Min GB/T2946
Measurement Range: | 1-50kg (customizable) |
---|---|
Force Measurement Accuracy: | Better Than ± 1% |
Displacement Resolution: | 0.01mm |
ST120FS Simplified Fully Automatic Sugar Hardness Range 0-50MPa Tester Trip 1-70mm Error ±1%
Measurement Range: | 0-50MPa |
---|---|
Indication Error: | ±1% |
Variable Indication: | <1% |
6 Samples Per Test Neutral Acid Washing Fiber Tester Measure 90min Relative Error ≤ 4%
Number Of Test Samples: | 6 Per Test |
---|---|
Cellulose Content Below 10%: | Absolute Value Error ≤ 0.4 |
Cellulose Content Above 10%: | Relative Error ≤ 4% |
Preset 5min Granular Activated Carbon Strength Tester ST-108 Speed 50r/Min GB/T 7702.3
Drum Speed: | 50r/min ± 2r/min |
---|---|
Steel Ball Diamete: | φ14.3mm±0.2mm |
Inner Diameter Of Drum: | φ80mm±0.2mm |
Time Measure Accuracy 0.01s Automatic Brinell Viscometer Water Bath RT-70 ℃ GB13731
Time Measurement Range: | 0-5000 Seconds |
---|---|
Time Measurement Accuracy: | ≤ 0.01 Seconds |
Temperature Control Range Of Water Bath: | Room Temperature -70 ℃ |
100ml Digital Burgundy Viscometer Error ± 0.5ml QB2354 Measuring Range 0-9.99mPa.S
Viscosity Measurement Range: | 0-9.99mPa.s |
---|---|
Display Resolution: | 0.01mPa.s |
Instrument Measurement Accuracy: | ±0.02mPa.s |