Automatic Pinstar Kinematic Viscosity Tester 1800W

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xMethods | The Viscosity Was Determined According To General Rule 0633 Of 2020 Chinese Pharmacopoeia | General Temperature Control Range | Room Temperature ~ 100.0℃(High Temperature To 150 ℃ Or Low Temperature To 0 ℃ Can Be Customized) |
---|---|---|---|
Temperature Control Accuracy | ±0.1℃(0.01 ℃ Can Be Customized) | Timing Range | 0.0s ~ 999.9s |
Timing Accuracy | 60min No More Than ±0.01% | Measuring Range | Pinot Viscosity Measuring Range: 0.6-17000mm2/s |
Service Environment Ambient Temperature | 10℃ ~ 35℃ | Service Environment Relative Humidity | ≤ 85% |
Temperature Sensor | Pt100 Platinum Resistance | Rated Power | 1800W |
Instrument Size | 380 * 450 * 550mm | Weight | 38kg |
Highlight | 1800W Automatic Pinstar Kinematic Viscosity Tester,Automatic Pinstar Kinematic Viscosity Tester |
ST204B Automatic Pinstar kinematic viscosity tester
ST204B automatic Pinstar kinematic viscosity tester is suitable for the design and manufacture of viscosity measurement method based on general principle 0633 of Chinese Pharmacopoeia in 2020 and <911> VISCOSITY-CAPILLARY VISCOMETER METHODS. This method adopts relative method to measure the time required for a certain volume of liquid to pass through the capillary under the action of gravity, so as to obtain the kinematic viscosity of the fluid.
ST204B automatic drug kinematic viscometer has a series of automatic functions, such as automatic constant temperature, automatic extraction, automatic timing, automatic calculation, automatic printing, automatic cleaning, automatic drying, etc. When in use, the test can be completed by one sample injection and clicking start.
Main technical indexes
Compliance standard: General Rule 0633 of Chinese Pharmacopoeia in 2020
● Temperature measurement range: room temperature - 100 ℃ (high temperature can be customized to 150 ℃ or low temperature 0 ℃);
● Temperature control accuracy: 0.1 ℃ (0.01 ℃ can be customized)
● Display mode: human inductive touch screen
● Operation process: put the sample into constant temperature, detect, calculate, clean the viscosity tube, dry, print the report automatically
● Viscosity tube clamp: made of 304 stainless steel, high and low temperature resistant graphite sliding bearing device
● Measuring range: Pinot viscosity measuring range: 0.6-17000mm2/s
● Temperature control range: 0 ℃~100.0 ℃ (high temperature can be customized to 150 ℃)
● Temperature control accuracy: 0.1 ℃
● Timing range: 0.0s~999.9s;
● Timing accuracy: no more than ± 0.01% for 60min;
● Detection method: photoelectric sensor detection
● Result output: at the same time, it can be equipped with U disk output function, and output to PC terminal for long-term storage
● Remote upgrade: with TCP network transmission function, software remote upgrade can be carried out later
● Account management: the account is managed by layers, and the main account and sub-account can be set with three-level management authority
● Account extension: audit tracking function (optional)
● Data storage: U disk data export function
● Data sharing: can be accessed into the group company's limis system (optional)
● Input extension: select barcode gun to scan and input sample information (optional)
● Printer: equipped with micro printer
● Power consumption of the whole machine: not more than 2000W.
● Working power supply: AC220V ± 10%; 50Hz
● Size and weight: 450 * 380 * 550mm 38kg
Methods | The viscosity was determined according to general rule 0633 of 2020 Chinese Pharmacopoeia |
General temperature control range | room temperature ~ 100.0℃(High temperature to 150 ℃ or low temperature to 0 ℃ can be customized) |
Temperature control accuracy | ±0.1℃; (0.01 ℃ can be customized) |
Timing range | 0.0s ~ 999.9s; |
Timing accuracy | 60min no more than ±0.01% |
Measuring range | Pinot viscosity measuring range: 0.6-17000mm2/s |
Service environment |
Ambient temperature 10℃ ~ 35℃, relative humidity ≤ 85%; |
Temperature sensor | Pt100 platinum resistance |
Rated power | 1800W |
Instrument size: 380 * 450 * 550mm Weight: 38kg |
packing list
S/N | Name | Quantity | Unit | Remarks |
1 | Host | 1 | set | |
2 | Ubbelohde special viscosity tube | 4 | piece | Comply with the pharmacopoeia |
3 | Special viscometer support | 1 | set | |
4 | Cleaning fluid conduit | 2 | piece | |
5 | Electric attractor | 1 | set | |
6 | power cord | 1 | piece | |
7 | Certificate warranty card | 1 | copy | |
8 | instructions | 1 | copy | |
9 | Printing paper | 2 | piece |