Precision Automatic Open Flash Point Tester Ac220v±10% Hydraulic Oil Flash Point Tester 50hz

Place of Origin CHINA
Brand Name Shandong Shengtai Instrument
Certification GB/T 3536、ASTMD 92
Model Number SH106B
Minimum Order Quantity 1
Packaging Details wooden case
Delivery Time 7-15 work days
Payment Terms T/T
Supply Ability 10000 sets/year

Contact me for free samples and coupons.

WhatsApp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Working Power Supply AC220V±10% 50Hz Temperature Measurement Range Room Temperature ~ 400℃
Repeatability Flash Point ≤150℃ Error ±2℃; Flash Point ≥150℃ Error ±3℃ Resolution 0.1℃
Precision 0.5% Heating Speed In Line With GB/T3536 Standard
Ignition Mode Electronic Ignition, Flame 3㎜~4㎜ Ambient Temperature (10~40)℃
Relative Humidity ≤80% Boundary Dimension 430 * 380 * 520 (mm)
About 15kg
Highlight

Precision automatic open flash point tester

,

220v automatic open flash point tester

,

Hydraulic automatic open flash point tester

Leave a Message
Product Description

SH106B Automatic open flash point tester

SH106B automatic open flash point tester is designed and manufactured according to the standard GB/T 3536 and ASTMD 92 "Determination of flash point and ignition point of petroleum products (Cleveland open cup method)".

Instrument according to the standard method of heating, automatic rise and fall, automatic ventilation, automatic ignition, automatic display, automatic locking flash point value, automatic printing results.

Automatic open flash point tester for gear oil hydraulic oil turbine oil ASTMD 92 Cleveland open cup method

After the test can be automatically cooled, to achieve the full automation of the work process.

ASTM D92 Automatic Cleveland Open Cup Flash Point Tester

It has the advantages of accurate measurement, good repeatability, stable performance and simple operation. It also supports the determination of GB/T1671-2008 plasticizer flash point

Hydraulic Oil flash point tester ASTM D92

ASTM D92 Automatic Cleveland Open Cup Flash Point Tester for Oil Testing

ASTM D92 Automatic Engine Oil Open Cup Flash Point Tester

China Manufacturer Price Automatic Digital Portable Open Cup Type Oil Flash and Fire Point Tester

Automatic open flash point tester for Turbine oil standard ASTMD 92 GB/T3536 Cleveland open cup method

Precision Automatic Open Flash Point Tester Ac220v±10% Hydraulic Oil Flash Point Tester 50hz 0

Product model SH106B
Product name Full-automatic open flash point tester
Manufacturer Shandong Shengtai Instrument Co., Ltd
Test items It can meet the requirements of petroleum, chemical, railway, aviation, electric power, commodity inspection and scientific research institutions for testing petroleum products
Compliance with standards National standard GB/T 3536 Petroleum Products - Determination of Flash Point and Flash Point (Cleveland Open Cup Method)
Simple technical features Full Chinese human-computer interface, no identification keyboard, with prompt menu and guided input function for parameters such as predictable temperature, sample number, atmospheric pressure, test date, etc.

 

Instrument features

1. The instrument adopts color LCD large screen display, full Chinese man-machine dialogue interface, no identification keyboard, for the parameters such as pre-value temperature, sample label, atmospheric pressure, test date, with prompt menu, oriented input function.

2. Simulation tracking displays the function curve of temperature rise and test time. It has the function of Chinese wrong operation software to prompt modification, and the function of test date, test time and other parameters to prompt.

3. Automatically correct the influence of atmospheric pressure on the test and calculate the correction value.

4. Differential detection, automatic correction of system deviation.

5. Scanning, detection and printing data are automatically completed, and the test arm automatically rises and falls.

6. Electronic ignition and forced air cooling

7. without automatic ignition of air source, improve the safety of the test

 

Main technical indexes and parameters

1. Working power supply: AC220V±10% 50Hz

2. Temperature measurement: range: room temperature ~ 400℃

3. Repeatability: flash point ≤150℃ error ±2℃; flash point ≥150℃ error ±3℃

4. Resolution: 0.1℃

5. Precision: 0.5%

6. Heating speed: in line with GB/T3536 standard

7. Ignition mode: electronic ignition, flame 3㎜~4㎜

8. Ambient temperature: (10~40)℃

9. Relative humidity:≤80%

10. Boundary dimension: 430 * 380 * 520 (mm) About: 15kg

Precision Automatic Open Flash Point Tester Ac220v±10% Hydraulic Oil Flash Point Tester 50hz 1

Working power supply AC220V±10%, 50Hz
Temperature measurement

room temperature ~ 400℃;

Repeatability: flash point ≤150℃ error ±2℃ flash point ≥150℃ error ±3℃

Resolution: 0.1℃

Precision: 0.5%

Heating speed in line with GB/T3536 standard
ignition mode electronic ignition, flame 3㎜~4㎜
ambient temperature (10~40)℃
relative humidity ≤80%
Boundary dimension: 430 * 380 * 520 (mm) About: 15kg

 

Packing list

S/N Name Quantity Unit Remarks
1 Automatic opening flash point meter 1 set  
2 Oil cup 1 piece  
3 AC power cord 1 piece  
4 Printing paper 1 piece  
5 Operating instruction 1 piece  
6 packing list 1 copy  
7 Certificate of approval 1 copy