Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Precision Automatic Open Flash Point Tester Ac220v±10% Hydraulic Oil Flash Point Tester 50hz

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xWorking Power Supply | AC220V±10% 50Hz | Temperature Measurement Range | Room Temperature ~ 400℃ |
---|---|---|---|
Repeatability | Flash Point ≤150℃ Error ±2℃; Flash Point ≥150℃ Error ±3℃ | Resolution | 0.1℃ |
Precision | 0.5% | Heating Speed | In Line With GB/T3536 Standard |
Ignition Mode | Electronic Ignition, Flame 3㎜~4㎜ | Ambient Temperature | (10~40)℃ |
Relative Humidity | ≤80% | Boundary Dimension | 430 * 380 * 520 (mm) |
About | 15kg | ||
Highlight | Precision automatic open flash point tester,220v automatic open flash point tester,Hydraulic automatic open flash point tester |
SH106B Automatic open flash point tester
SH106B automatic open flash point tester is designed and manufactured according to the standard GB/T 3536 and ASTMD 92 "Determination of flash point and ignition point of petroleum products (Cleveland open cup method)".
Instrument according to the standard method of heating, automatic rise and fall, automatic ventilation, automatic ignition, automatic display, automatic locking flash point value, automatic printing results.
Automatic open flash point tester for gear oil hydraulic oil turbine oil ASTMD 92 Cleveland open cup method
After the test can be automatically cooled, to achieve the full automation of the work process.
ASTM D92 Automatic Cleveland Open Cup Flash Point Tester
It has the advantages of accurate measurement, good repeatability, stable performance and simple operation. It also supports the determination of GB/T1671-2008 plasticizer flash point
Hydraulic Oil flash point tester ASTM D92
ASTM D92 Automatic Cleveland Open Cup Flash Point Tester for Oil Testing
ASTM D92 Automatic Engine Oil Open Cup Flash Point Tester
China Manufacturer Price Automatic Digital Portable Open Cup Type Oil Flash and Fire Point Tester
Automatic open flash point tester for Turbine oil standard ASTMD 92 GB/T3536 Cleveland open cup method
Product model | SH106B |
Product name | Full-automatic open flash point tester |
Manufacturer | Shandong Shengtai Instrument Co., Ltd |
Test items | It can meet the requirements of petroleum, chemical, railway, aviation, electric power, commodity inspection and scientific research institutions for testing petroleum products |
Compliance with standards | National standard GB/T 3536 Petroleum Products - Determination of Flash Point and Flash Point (Cleveland Open Cup Method) |
Simple technical features | Full Chinese human-computer interface, no identification keyboard, with prompt menu and guided input function for parameters such as predictable temperature, sample number, atmospheric pressure, test date, etc. |
Instrument features
1. The instrument adopts color LCD large screen display, full Chinese man-machine dialogue interface, no identification keyboard, for the parameters such as pre-value temperature, sample label, atmospheric pressure, test date, with prompt menu, oriented input function.
2. Simulation tracking displays the function curve of temperature rise and test time. It has the function of Chinese wrong operation software to prompt modification, and the function of test date, test time and other parameters to prompt.
3. Automatically correct the influence of atmospheric pressure on the test and calculate the correction value.
4. Differential detection, automatic correction of system deviation.
5. Scanning, detection and printing data are automatically completed, and the test arm automatically rises and falls.
6. Electronic ignition and forced air cooling
7. without automatic ignition of air source, improve the safety of the test
Main technical indexes and parameters
1. Working power supply: AC220V±10% 50Hz
2. Temperature measurement: range: room temperature ~ 400℃
3. Repeatability: flash point ≤150℃ error ±2℃; flash point ≥150℃ error ±3℃
4. Resolution: 0.1℃
5. Precision: 0.5%
6. Heating speed: in line with GB/T3536 standard
7. Ignition mode: electronic ignition, flame 3㎜~4㎜
8. Ambient temperature: (10~40)℃
9. Relative humidity:≤80%
10. Boundary dimension: 430 * 380 * 520 (mm) About: 15kg
Working power supply | AC220V±10%, 50Hz |
Temperature measurement |
room temperature ~ 400℃; Repeatability: flash point ≤150℃ error ±2℃ flash point ≥150℃ error ±3℃ Resolution: 0.1℃ Precision: 0.5% |
Heating speed | in line with GB/T3536 standard |
ignition mode | electronic ignition, flame 3㎜~4㎜ |
ambient temperature | (10~40)℃ |
relative humidity | ≤80% |
Boundary dimension: 430 * 380 * 520 (mm) About: 15kg |
Packing list
S/N | Name | Quantity | Unit | Remarks |
1 | Automatic opening flash point meter | 1 | set | |
2 | Oil cup | 1 | piece | |
3 | AC power cord | 1 | piece | |
4 | Printing paper | 1 | piece | |
5 | Operating instruction | 1 | piece | |
6 | packing list | 1 | copy | |
7 | Certificate of approval | 1 | copy |