0.5 Level Semi-automatic potential dropper Resolution 0.01pH Data storage 2000 sets

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xMeasurement Range | PH:(-2.00~20.00), MV :(-1999~+1999)mV | Temp Measurement | (0-100.0) ℃ |
---|---|---|---|
Repetitive Error In Capacity Analysis | 0.2% | Resolution | 0.01pH , 0.1mV , 0.1 ℃ |
Data Storage | 2000 Sets | Normal Working Environment Of The Instrument | Temp : 5-40 ℃ Humidity: ≤ 85% |
Size | (165 × 90 × 32) Mm | Weight | 310g |
ST-13 Semi-automatic potential dropper
The ST-13 semi-automatic potentiometric titrator is an instrument that uses potentiometric titration to determine the endpoint of titration by measuring potential changes during the titration process. Mainly used for chemical analysis of various components in various industries such as universities, research institutions, petrochemicals, pharmaceuticals, drug testing, metallurgy, etc
Main performance characteristics:
● Output mode: 7-inch color touch screen
● Control mode: Electromagnetic valve controls dripping, and the host is integrated with the magnetic stirrer
● Automation: It has intelligent functions such as automatic calibration, automatic temperature compensation USB output, clock display, and self diagnostic information.
● Result output: It can also be equipped with a USB drive output function to output to the PC for long-term storage
● Analysis selection: For capacity analysis using potentiometric titration in experimental applications
● Titration endpoint: pH value or potential can be controlled for titration, and the titration endpoint can be controlled according to the set potential (pH)
● Titration mode: with manual, automatic, and controlled (constant pH/potential) titration modes
● Potential value: can be used to determine the pH value of the sampled aqueous solution and measure the potential value of the electrode
Technical Parameter:
Instrument level | Level 0.5 |
Input current | ≤ 6×10-12 A |
Input impedance | ≥ 1×10 11 Ω |
Measurement range |
pH:(-2.00~20.00), mV :(-1999~+1999)mV |
Temp measurement | (0-100.0) ℃ |
Repetitive error in capacity analysis | 0.2% |
elative accuracy of instrument pH | ± 0.03pH |
Resolution | 0.01pH , 0.1mV , 0.1 ℃ |
Stability of electronic unit | (± 0.3mV ± 1 word)/3h |
Titration control sensitivity |
pH: ± 0.1pH mV: ± 5mV |
Basic error of electronic unit |
PH : ± 0.03 pH Mv : ± 5mV Temp : ±0.3℃ |
End point setting range | (-2~20.00) pH or (-2000~2000) mV |
Power supply | AC (220 ± 22)V (50 ± 0.5) Hz |
Data storage | 2000 sets |
Storage content | name, endpoint, sample concentration, date |
Normal working environment of the instrument |
Temp : 5-40 ℃ Humidity: ≤ 85% |
Size | (165 × 90 × 32) mm |
Weight | 310g |
● Instrument level : Level 0.5
● Input current : ≤ 6×10-12 A
● Input impedance : ≥ 1×10 11 Ω
● Measurement range : pH:(-2.00~20.00) mV :(-1999~+1999)mV
● Temperature measurement : (0-100.0) ℃
● Repetitive error in capacity analysis : 0.2%
● Relative accuracy of instrument pH : ± 0.03pH
● Resolution : 0.01pH/0.1mV 0.1 ℃
● Stability of electronic unit : (± 0.3mV ± 1 word)/3h
● Titration control sensitivity : pH: ± 0.1pH mV: ± 5mV
● Basic error of electronic unit : PH: ± 0.03 pH mV: ± 5mV Temperature: ±0.3℃
● End point setting range : (-2~20.00) pH or (-2000~2000) mV
● Power supply : AC voltage (220 ± 22) V frequency (50 ± 0.5) Hz
● Data storage : 2000 sets
● Storage content: name, endpoint, sample concentration, date
● Normal working environment of the instrument : Temperature: 5-40 ℃
Humidity: ≤ 85%
● Size : (165 × 90 × 32) mm
● Weight : 310g
Note: The appearance pictures, dimensions, volume, and weight of the instrument are for reference only. If there are any updates to the instrument, there may be slight changes without prior notice.
Packing list
Number | Name | Unit | Quantity | Notes |
1 | Host | Tower | 1 | |
2 | PH composite electrode | Branch | 1 | E-201-9 |
3 | Temperature electrode T-10-Q | Branch | 1 | |
4 | Solenoid valve | Cover | 1 | |
5 | Electrode rod | Root | 1 | |
6 | Buret clamp | Cover | 1 | |
7 | Power line | Strip | 1 | |
8 | Operation instructions | Share | 1 | |
9 | Packing list | Share | 1 | |
10 | Certificate of conformity | Share | 1 |
Instrument Quality Assurance Certificate:
Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:
----The provided instrument materials are brand new, meet quality standards, and have a manufacturer's certificate of conformity;
----The materials and main components provided meet the technical requirements specified in the technical documentation;
----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).
----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.
----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.
----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.